Interlogix 2500 Series User Manual

Installation instructions, 2500 series aluminum housing, Introduction

Advertising
background image

1030557C • August 2006

Copyright © 2006, GE Security Inc.

2500 Series Aluminum Housing

Installation Instructions

Introduction

This is the GE 2500 Series Aluminum Housing Installation
Instructions
for models 2505A-L, 2507A-L, 2507AD, 2507AH.

Installation

To install models 2505A-L, 2507A-L, 2507AD do the following:
1.

Mount the switch and magnet so both labels read in the

same direction (Figure 1). Use the screws supplied or 18/8
stainless steel screws.

Note:

Switch position and gap distances will be reduced
when switch and magnet are positioned incorrectly.

Figure 1. Line up the labels

To install model 2507AH, do the following:
1.

Mount switch in desired location.

2.

Attach an ohmmeter to the black and white wires. The
meter should read infinity with the magnet away from the
switch.

3.

Bring the magnet toward the switch until the meter reads

zero ohms. Mark this position.

4.

Bring the magnet closer to the switch until the meter reads
infinity. Mark this position.

5.

Position the magnet between the two marks.

6.

Align the magnet and switch so the labels read in the same
direction. With the magnet positioned in this manner, the

switch will be harder to defeat with an external magnet.

Lead functions

Here are the lead colors and functions:

Specifications

Product ordering

GE

Security

GE

Security

2 in. (5.08 cm)

3 in. (7.62 cm)

0.5 in.
(1.27 cm)

1 i

n.

(2

.54 cm)

Mounting

holes
0.156 in.
(4 mm) dia.

Magnet
included
(part no. 1920)

Lead color

Function

Black

Common

White

Closed loop (NO)

Red

Open loop (NC)

Form A (2505A)

Voltage:

100 V max.

Current:

0.5 A max.

Power:

7.5 W max.

Form C (2507A, 2507AH, 2507AD)

Voltage:

30 V max.

Current:

0.25 A max.

Power:

3.0 W max.

Form A (2505A) ULC specifications

Voltage:

30 V max.

Current:

50 mA max.

Form A (2505A) European Union specification

Voltage:

48 V max.

Current:

0.5 A max.

Model number

Loop type

Electrical configuration Finish

Gap distance (make)

Lead type

Listing

2505A-L

Closed

NO

Anodized

Up to 3 in.

3 ft. stainless steel armored cable

UL, ULC

2507A-L

Open or closed

SPDT

Anodized

Up to 3 in.

3 ft. stainless steel armored cable

UL, ULC

2507AD-L

Open or closed

DPDT

Anodized

Up to 1.5 in.

3 ft. stainless steel armored cable

UL

2507AH-L

Open or closed

SPDT

Anodized

0.75 in. min, 2.5 in. max

3 ft. stainless steel armored cable

UL

Technical support

Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada).

Outside the toll-free area: Contact your local dealer.

www.gesecurity.com

Advertising