Manual override for bi-rotational power units – Lippert Components LCI Electronic/Hydraulic Leveling & Slideout User Manual
Page 11
Advertising
Rev: 07.14.2014
Page 11
Untitled-1
Fig. 9
Fig. 10
Manual Override for Bi-Rotational Power Units
1. Remove protective label (Fig. 9A).
2. Manually open jack valves with a 5/32" hex wrench (Fig. 7).
3. Using a 1/4" hex bit, insert into auxiliary drive device, i.e. cordless drill or power drill.
4. Insert hex bit into coupler found under protective label (Fig. 10).
5. Run drill forward or clockwise to extend jacks and in reverse or counterclockwise to retract jacks.
6. Close the manual override on the valves that were manually opened (Fig. 8).
Fig. 7 - Bi-Rotational
Fig. 8 - Bi-Rotational
Clockwise for manual override
Counter-clockwise for normal
operation
A
Forward or clockwise to extend; reverse or
counterclockwise to retract.
Protective Label (A)
Advertising