12

6.1

Boom Frame Roll Sensor Mounting

1. Install the roll sensor with the lowest serial number onto the roll sensor tab using the #6

hex head machine screws provided (M05) (Figure 9). Tighten screws to 10 in-lbs (1.1

Nm). The roll sensor must be mounted with the connector facing the right boom.

Ensure the boom frame roll sensor does not collide with any parts and the cable
has sufficient slack for the boom to travel though its entire range of motion.

Figure 9: Boom Frame Roll Sensor Mounting