TeeJet 500 SLURRY COMPUTER User Manual

Page 13

Advertising
background image

T

EE

J

ET

500

S

LURRY COMPUTER OPERATORS MANUAL

S

ETTINGS

13

WARNINGS

The following audible and visual warnings can be encoded:

Key

Description

Warning on.

Warning off.

Appl. rate:

Warning when the actual rate exceeds the encoded maximum
allowed error percent, plus warning on/off.

Amount left:

Warning when the encoded amount remaining in the tank is
reached, plus warning on/off.

Max.

speed:

Warning when the encoded maximum forward speed is
reached, plus warning on/off.

Rpm distributor:

Warning when the encoded minimums distributor speed is

reached, plus warning on/off.

Rpm pump:

Warning when the encoded minimums pump speed is
reached, plus warning on/off.

Rpm PTO:

Warning when the encoded minimums PTO speed is reached,
plus warning on /off.

We recommend switching off any warnings that are not used.

EMPTY TANK FUNCTION

It is possible, when using the Empty tank function, to automatically transfer the
encoded tank volume into “Ton left”.
Each time spreading is stopped, either via the start/stop button or via the selected
implement sensor, a pop-up menu is shown from which it is possible to select if
the tank is empty.
The Empty tank menu is shown when turning at the headland. If the spreader is
not empty simply start spreading again and the pop-up menu disappears
automatically.
When the tank is empty then the encoded tank volume can be transferred
automatically to “Ton left” by pressing the ENTER key.
The Empty tank pop-up menu can be removed (cancelled) by pressing the C key.
Use this for, e.g. encoding different settings, etc.

Advertising