3-3

98-05019

Rev- 1

TASC 6200/6500

CE & S

TANDARD

V

ERSION

The programmed rates and alternate rates can be viewed with the vehicle stopped, booms OFF, and the TASC
console in the OPERATE or SET-UP modes. Turn the display selector to L & CHEMICALS, APPL. RATE and
select one of the product switches 1,2,3 or L. Switching the rate selection switch for that channel between ON
and ALT-RATE displays both preset rates. To view the rates set for the C product, turn the display selector
switch to CARRIER, APPL. RATE and select ON or ALT-RATE with C Product Switch. Normal and alternate
rates can be changed in the SET-UP mode using the INC/DEC switch.

CAUTION: Operating in an alternate application rate is not a normal condition. The TASC console will
continue to remind the operator that a non-standard rate has been selected. TASC will flash the channel
indicator light and display a flashing RATE message on the display.

3.5.2 CHANGING THE PERCENT RATE ON THE CARRIER CHANNEL ONLY

The TASC console allows the operator to change the application rate of the C channel product by a percentage
amount using the INC/DEC switch. The change does not affect the other products. The percentage change
affects either the normal or alternate rate of the channel, depending on which has been chosen with the Product
Switch.

The operator selects the CARRIER, APPL. RATE position while in the OPERATE mode. The console displays
the actual application rate while applying (or the target rate with the vehicle at rest). Toggling the INC/DEC
switch changes the channel rate up or down by the percentage set in the % RATE/SET-UP position. The display
momentarily shows the new target rate of channel C before displaying the actual discharge rate. The percent rate
change is canceled by switching out of the CARRIER, APPL. RATE function.

CAUTION: Operating with a modified application rate is not a normal condition. The TASC will con-
tinue to remind the operator that a non-standard rate has been selected. TASC will beep an alarm and
display a flashing % RATE message on the display.

3.5.3 CHANGING THE PERCENT RATE OF CHANNELS 1, 2, 3 AND L
SIMULTANEOUSLY

The TASC console allows the operator to change the application rate of channels 1,2,3 and L by a percentage
amount using the INC/DEC switch. The change does not affect channel C. The percentage change does affect
either the normal or alternate rate of each channel, depending on which has been chosen with the Product
Switch.

The operator selects the L & CHEMICALS, APPL. RATE position while in the OPERATE mode. The console
displays the actual application rates while applying (or the target rates with the vehicle at rest). Toggling the
INC/DEC switch changes rates up or down by the percentage set in the % RATE/SET-UP position. The display
momentarily shows the new percentage target rate before displaying the actual discharge rates. The percent rate
change is canceled by switching out of the L & CHEMICALS, APPL. RATE function.

CAUTION: Operating with a modified application rate is not a normal condition. The TASC console will
continue to remind the operator that a non-standard rate has been selected. TASC will beep an alarm and
display a flashing % RATE message on the display.

3.5.4 CHANGING THE PERCENT RATE OF ALL CHANNELS SIMULTANEOUSLY

The TASC console allows the operator to change the application rate of all channels by a percentage amount
using the INC/DEC switch. The percentage change affects either the normal or alternate rate of each channel,
depending on which is chosen with the rate selector switch.

The operator selects the % RATE position while in the OPERATE mode. The console displays 100. Toggling
the INC/DEC switch changes all rates up or down by the percentage set in the % RATE/SET-UP position. The
display shows the new percentage target. The percent rate change is canceled by switching out of the % RATE
function.

CAUTION: Operating with a changed application rate is not a normal condition. The console will
continue to remind the operator, that a non-standard rate has been selected. TASC will beep an alarm
and display a flashing % RATE message on the display.