ChaptEr 5 - FEatUrES

boost Mode

There may be instances where ”on the go” increased or decreased

chemical application may be required in certain areas of your field.

In situations like this, the Plus key and Minus key will allow

you to easily make the necessary adjustments. The boost mode can

be activated while spraying in the Auto mode by pressing either the

Plus key or Minus key once. With each subsequent press of

the Plus key , the application rate will be increased by 10%. Each

subsequent press of the Minus key will reduce the application rate

by 10%.
If the Plus key or Minus key is pressed once inadvertently

during operation, a delay of three seconds will deactivate the boost

mode. Succeeding presses will change the target rate as explained

above.
ExAMPLE: If increasing the application rate by 10%, press the

Plus key once to activate the boost mode, and a

second time to make the 10% increase. If decreasing the

application rate by 10%, repeat the above procedure using

the Minus key .

The application rate changes are monitored in the display, as you make

them. The display will show UP 10, UP 20, dn 20, dn 30,

etc. This will be displayed for approximately 3 seconds before the

display returns to reading actual application rates. When making the

application rate changes, it is not necessary to set the Auto/Man to

“MAN” mode.
To return the application rate to its programmed status, you may use

the Plus key or Minus key individually to step back to the

application rate in 10% increments, or press them simultaneously to

return to the programmed target application rate.
NOTE: While in the boost mode, the target symbol will flash at the

top of the console display, to remind the operator they are not

spraying at the target application rate.

area/Volume Feature

The 844 Sprayer Control will count application acres (hectares) and

measure total volume applied while the master boom switch is in the

“on” position. The area counter will measure treated acres (hectares)

and is dependent on the value programmed for nozzle spacing on page

15. The volume measure is dependent on flow meter pulses and is

available on flow based models only.
The lower right of the display window will alternately show the treated

area sprayed and the total volume applied since the last clearing of the

area counter/volume measure.

To clear the area counter/volume measure, press and hold the Plus

key and Minus key simultaneously for three (3) seconds while

viewing the normal operating mode.
NOTE: The area memory counter/volume measure only works when

the Master Boom Switch is turned “ON”.

NOTE: If you are using a pressure based controller, the Volume feature

is disabled. The total area will then be displayed at all times

Flow rate Feature

The 844 Sprayer Control will measure a flow rate moving through

the flow meter in GPM (LPM) {Imp GPM}. This feature is activated by

pressing and holding the Program key while spraying in the normal

operating mode. The flow rate display replaces the area/volume display

in the lower right portion of the display.
Any time the Program key is pressed while spraying in the normal

operating mode the flow rate will be displayed. Releasing the Program

key will cause the display to return to area/volume.
This feature can be used for tip calibration or for calibrating the flow

meter. Refer to page 29 of this manual for flow meter calibration

procedures.
NOTE: Not all 844 models contain this feature. If the display makes no

change when pressing on the Program key while spraying

in the normal operating mode, then this feature is not available

with this console.

application alarm

If the 844 senses a continuous discrepancy of 10% or more between

the Target Application Rate and the Actual Application Rate, the

application rate units (GPA, G/1000 ft

2

or l/ha) will flash in the display

window. This alarms the operator to a problem with the sprayer

plumbing, operation or programming.

no Flow alarm

If the 844 stops receiving pulses from the flow meter, the turbine

symbol

will flash at the top of the display. This alarm indicates

that the flow meter has stalled and alerts the operator that there is a

problem with the flow meter or elsewhere in the system.
This alarm will occur only when the Master Boom Switch and at least

one boom toggle switch is “on”.