Troubleshooting (cont'd)
Operational Conditions (cont'd)
HIGH TEMPERATURE SHUT OFF SYSTEM
1. Before beginning, turn “OFF” electrical power supply
to
the water heater.
AWARNING
HAZARD OF ELECTRICAL SHOCK! Before removing
any access panels or servicing the water heater,
make sure the eiectrical supply to the water heater
is turned "OFF". Failure to do this could result in
DEATH, SERiOUS BODiLY INJURY. OR PROPERTY
DAMAGE.
2. Remove the two screws securing the upper access panel and
remove panel.
3. Remove the flap of insulation to expose the opening.
4. Reset the high limit by pushing in the red button marked
“RESET”.
RESET BUTTON
5. Press the insulation back in place so that it completely cov
ers the high hmit and element.
6. Replace the upper access panel.
7. Turn “ON” electric power to the water heater.
A CAUTION
If the high limit must be reset again, cail Maytag
Customer Service at 1-800-788-8899 for an autho
rized servicer to find out why the high limit turned
"OFF" the electric power.
NOT ENOUGH OR NO HOT WATER
1. In a new installation, the water heater may not be proper
ly connected. Make sure the cold water supply valve is
open. Review and check piping installation. Make sure
that the cold water line is connected to the cold water
inlet to the water heater and the hot water line to the hot
water outlet on the water heater,
2. Make sure the electrical supply to your water heater is
“ON”.
3. Check for loose or blown fuses in your water heater cir
cuit. Circuit breakers weaken with age and may not han
dle their rated load and should be replaced,
4. Make certain the disconnect switch, if used, is in the
“ON” position.
5. Check to see the electric service to your house has not
been intermpted. If this is the case, contact the electric
company.
6. Is the programmable thermostat set to the desired tem
perature? See “Temperature Regulation” section.
7. If you had experienced very hot water and now no hot
water, the problem may be due to the high temperature
shut off system. See “High Temperature Shut Off
System” in the “Troubleshooting” section,
8. During very cold weather, the incoming water will also be
colder and it will require a longer time to become heated,
9.
The hot water usage may exceed the capacity of the water
heater. If so, wait for water heater to recover after abnor
mal demand. Also examine pipes and faucets for possible
water leaks.
10. If you can not determine the problem, then call the
Maytag Service Department.
WATER IS TOO HOT
Adjust the thermostat to a lower setting. See the
“Temperature Regulation” section on page 23.
33