Troubleshooting, Problem cause solution – Troy-Bilt 01919-1 User Manual

Page 14

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Section

7

Troubleshooting

TROUBLESHOOTING

Problem

Cause

Solution

No AC output is available,

but engine is running.

1.

Circuit breaker is open.

2.

Poor connection or defective cord set.

3.

Connected device is bad.

4.

Fault in generator.

1.

Reset circuit breaker.

2.

Check and repair.

3.

Connect another device that is in

good condition.

4.

Contact Authorized Service Facility.

When loads are

connected, engine runs

good but bogs down.

1.

Short circuit in a connected load.

2.

Generator is overloaded.

3.

Engine speed is too slow.

4.

Shorted generator circuit.

1.

Disconnect shorted electrical load.

2.

See "Don't Overload Generator".

3.

Contact Authorized Service Facility.

4.

Contact Authorized Service Facility.

Engine shuts down during

operation.

Out of gasoline.

Fill fuel tank.

Engine lacks power.

Load is too high.

See "Don't Overload Generator".