Figure  5-­‐2

Basic  PTZ  Configuration  Interface  

2) Configure  the  following  settings:    

!

Basic  Parameters:  Enable/disable  proportional  pan  and  preset  freezing,  set  the  preset  
speed,  keyboard  control  speed,  and  auto  scan  speed.  

!

Proportional  Pan:  If  you  enable  this  function,  the  pan/tilt  speeds  change  according  
to  the  amount  of  zoom.  When  there  is  a  large  amount  of  zoom,  the  pan/tilt  speed  
will  be  slower  for  keeping  the  image  from  moving  too  fast  on  the  live  view  image.  

!

Preset  Freezing:  This  function  enables  the  live  view  to  switch  directly  from  one  
scene  defined  by  a  preset  to  another,  without  showing  the  middle  areas  between  
these  two,  to  ensure  the  surveillance  efficiency.  It  can  also  reduce  the  use  of  
bandwidth  in  a  digital  network  system.  

NOTE:

 

Preset  freezing  function  is  invalid  when  you  calling  a  pattern.  

!

Preset  Speed:  You  can  set  the  speed  of  a  defined  preset  from  1  to  8.  

!

Keyboard  Control  Speed:  Define  the  speed  of  PTZ  control  by  a  keyboard  as  Low,  
Normal  or  High.  

!

Auto  Scan  Speed:  The  dome  provides  5  scan  modes:  auto  scan,  tilt  scan,  frame  scan,  
random  scan  and  panorama  scan.  The  scan  speed  can  be  set  from  level  1  to  40.  

!

Zooming  Speed:  The  zoom  speed  is  adjustable  from  level  1  to  3.  

!

PTZ  OSD:  Set  the  on-­‐screen  display  duration  of  the  PTZ  status.  

!

Zoom  Status:  Set  the  OSD  duration  of  zooming  status  as  2  seconds,  5  seconds,  10  
seconds,  Always  Close  or  Always  Open.  

!

PT  Status:  Set  the  azimuth  angle  display  duration  while  panning  and  tilting  as  2  
seconds,  5  seconds,  10  seconds,  Always  Close  or  Always  Open.  

!

Preset  Status:  Set  the  preset  name  display  duration  while  calling  the  preset  as  2  
seconds,  5  seconds,  10  seconds,  Always  Close  or  Always  Open.  

!

Power-­‐off  Memory:  The  dome  can  resume  its  previous  PTZ  status  or  actions  after  it  
restarted  from  a  power-­‐off.  You  can  set  the  time  point  of  which  the  dome  resumes  its  
PTZ  status.  You  can  set  it  to  resume  the  status  of  30  seconds,  60  seconds,  300  seconds  or  
600  seconds  before  power-­‐off.  