Table 2, System power requirements (com 840, 1.6 ghz core – ADLINK MilSystem 735 User Manual
Page 7

MilSystem Setup
MilSystem
User’s Guide
3
lists the current draw values of the MilSystem with the COM 840 and the EBX Baseboard.
Operating configurations:
•
In-rush operating configuration includes one COM 840, 2GB DDR2 RAM, AMI BIOS, EBX
Baseboard, AC/DC external digital power supply, DC/DC internal power module, LCD monitor, SATA
2.5" HDD, keyboard and mouse.
•
Idle operating configuration includes the same items as the In-rush configuration.
•
BIT (Burn-In-Test) operating configuration includes the same items as the Idle configuration as well as
four serial loop backs, one parallel port with loop back, two Ethernet connections, and four external
USB Compact Flash loop backs.
Table 2. System Power Requirements (COM 840 with EBX Baseboard, 1.6 GHz Core
TM
2 Duo CPU)
Input Type
In-rush Current
(@ 104.26W Power)
Typical Idle Current
(@ 37.96W Power)
Typical BIT Current
(@ 48.43W Power)
+14VDC
7.45A 2.71A
3.46A
+16VDC
6.52A 2.38A
3.03A
+18VDC
5.79A 2.11A
2.69A
+20VDC
5.21A
1.90A
2.42A
+22VDC
4.74A 1.73A
2.20A
+24VDC
4.34A
1.58A
2.02A
+26VDC
4.01A 1.46A
1.86A
+28VDC
3.72A 1.36A
1.73A
+30VDC
3.48A 1.27A
1.61A
+32VDC
3.26A 1.19A
1.51A