Environmental specifications, Table 3, Table 4 – ADLINK MilSystem 735 User Manual
Page 8: Environmental requirements

MilSystem Setup
4
User’s Guide
MilSystem
lists the current draw values of the MilSystem with the LittleBoard 800.
Operating configurations:
•
In-rush operating configuration includes one LittleBoard 800, 1GB DDR RAM, AMI BIOS, AC/DC
external digital power supply, DC/DC internal power module, CRT monitor, HDD, keyboard and
mouse.
•
Idle operating configuration includes the same items as the In-rush configuration.
•
BIT (Burn-In-Test) operating configuration includes the same items as the Idle configuration as well as
four serial loop backs, one parallel port with loop back, two Ethernet connections, four external USB
flash drives, and one Compact Flash card.
Environmental Specifications
provides the most efficient operating and storage condition ranges required for this system with the
LittleBoard 735, LittleBoard 800, and COM 840.
Table 3. System Power Requirements (LittleBoard 800, 1.4 GHz Pentium M CPU)
Input Type
In-rush Current
(@ 170.88W Power)
Typical Idle Current
(@ 9.54W Power)
Typical BIT Current
(@ 13.18W Power)
+14VDC
12.21A
0.68A
0.94A
+16VDC
10.68A
0.60A
0.82A
+18VDC
9.49A
0.53A
0.73A
+20VDC
8.54A
0.48A
0.66A
+22VDC
7.77A
0.43A
0.60A
+24VDC
7.12A
0.40A
0.55A
+26VDC
6.57A
0.37A
0.51A
+28VDC
6.10A
0.34A
0.47A
+30VDC
5.70A
0.32A
0.44A
+32VDC
5.34A
0.30A
0.41A
NOTE
Extended temperature range available only on extended temperature tested
(ETT) systems.
Table 4. Environmental Requirements
Temperature
Humidity
Operating
Storage
Extended
Operating
Non-operating
-20
° to +65°C
(-4
° to +149°F)
–55° to +85°C
(–67° to +185°F)
–40° to +75°C
(–40° to +167°F)
5% to 90%
relative humidity,
non-condensing
5% to 95%
relative humidity,
non-condensing