Dunkirk Excelsior EXB Series User Manual

Page 16

Advertising
background image

16

16.

Connect Field Wiring. See “13 - Electrical

Connections” on page 34.
A. Route wire harness from burner to Limit control

through rear jacket panel. See Figure 15, Page 17.

Connect molex plug on burner wire harness to its

receptacle on limit control.

B. If optional manual reset high temperature limit is not

used, ensure supplied jumper is installed.

C. Connect the wiring harness from limit control to

circulator. See Figure 15, Page 17.

D. 120 volt power supply field wiring connects to limit

control. Provide appropriate overcurrent protection

and service disconnect switch.

E. Wire power supply. See Figure 15, Page 17.

Connect green wire to grounding lug. When

installing wiring through hole in Limit, use anti-

abrasion cable clamp. Connect black “hot” wire to L1

of terminal block, white “N” wire to L2 of terminal

block.

17.

Install top panel. Place on top of side panels. Position

tabs in top panel into slots in side panels. Push top

panel toward back of boiler. Install rear panel screws.

18.

Install drain valve. Install drain valve with hose

connection facing right or left. This allows clearance

for swing door to open and close with drain and

hose attached. Verify connection is water tight. See

Figure 16, Page 17.

19.

Close burner swing door.
A. Use one hand to hold door in position by applying

pressure directly to door while re-installing securing

hardware with your opposite hand. Always install

non-hinged side latching hardware first, then install

hinged side hardware. Apply additional pressure

while hand tightening hardware as far as possible,

then release pressure.

Table 4

- BAFFLES & LINERS

Sections

Liner

Liner

Length

Baffles

4

Oval

4”

9”

5**

V SHAPE

9”

12”

6

V SHAPE

12”

15”

7

V SHAPE

14”

NONE

** 9” V liner used only on Models 5115 and 5135

and only with Beckett NX burner. All other 5 section

models and burner combinations use no liner.

Figure 11

- Oval Liner

Figure 12 - V-Shaped Liner

Figure 13 - 3rd Pass Baffles

8 - BOILER ASSEMBLY

Advertising