PARTS LIST FOR VENTING KITS
AND COMPONENTS

DESA (5"/8") Pipe & Vent Kits
Number Description
P58-6

6" Section Double Wall Pipe,
Galvanized

P58-12

12" Section Double Wall Pipe,
Galvanized

P58-24

24" Section Double Wall Pipe,
Galvanized

P58-36

36" Section Double Wall Pipe,
Galvanized

P58-48

48" Section Double Wall Pipe,
Galvanized

PA58-712 Adjustable 7"-12" Section Double

Wall Pipe, Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

VKG-58 Ground Floor Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
16 Screws)

VKB-58

Basement Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
4' Pipe, 90° Elbow, 20 Screws)

VKS-58

Snorkel Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
36" Snorkel Termination, 4' Pipe,
1' Pipe, 90° Elbow, 26 Screws)

VENTING INSTALLATION

Continued

Number Description
VKR-58 Roof Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Flue Restrictor,
Vertical High Wind Termination,
2' Pipe, 4' Pipe, Wall Firestop,
Storm Collar, Roof Flashing
[0/12 - 6/12], 26 Screws)

VKC-58 Corner Vent Kit, Galvanized

(Includes 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Termination, 6" Pipe,
90° Elbow, 18 Screws)

HHTK-58 High Wind Round Horizontal

Termination Kit (Includes Round
Termination, Wall Firestop, 45°
Elbow)

HHT-58

High WInd Round Horizontal
Termination Kit, Galvanized

HTS-58

Horizontal Square Termination,
Galvanized

HTKS-58 Horizontal Square Termination Kit

(Includes: Square Termination,
Wall Firestop, 45° Elbow)

VT-58

Vertical Round Termination,
Galvanized

ST-58-14 14" Snorkel Termination, Galva-

nized

ST-58-36 36" Snorkel Termination, Galva-

nized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch,

Galvanized

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch,

Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff, Galva-
nized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing - For use with
HTS-58

RF-58

Flat Roof Flashing

PF58-927 Flex Pipe Section 9" to 24"
PF58-1236 Flex Pipe Section 12" to 36"
PF58-1854 Flex Pipe Section 18" to 54"
VKF58-927 Flex Kit (Includes Flex Pipel Sec-

tion 9" to 27", Wall Firestop and
Horizontal Square Termination)

Figure 25 - Recommended 12" Extension

for High Altitude Installation

45° Starter
Elbow

12"
Extension