SkyRC e6650 User Manual

Page 23

Advertising
background image

- 22 -

This program is only suitable for charging Pb (lead-acid) battery with

nominal voltage from 2 to 20V. Pb(lead-acid)battery is completely

different from NiCd/NiMH battery. These batteries can only deliver

current lower in comparison to their capacity. The same restriction

applies to the charging process. Consequently, the optimum charge

current can only be 1/10 of the capacity. Pb battery can not be used

for fast-charging, please follow the instructions provided by the

battery manufacturer.

Due to the chemistry characteristic of Pb battery, the cut off point

may be difficult to detect sometimes. We recommend user to use

CAPACITY CUT OFF feature to protect the battery.

You can press START/ENTER key to make it blink and alter the

value of parameters using INC or DEC key, press START/ENTER

key to store the value.

CHARGING PB (LEAD-ACID) BATTERY IN THE CHARGE MODE

CHARGING PB (LEAD-ACID) BATTERY IN THE CHARGE MODE

Set up the charge current on the left and

nominal voltage on the right. Range of

discharge current is 0.1-1.0A, the voltage

should match the battery being charged.

Press START/ENTER key for more than 3

seconds to start charging.

DISCHARGING OF THE PB BATTERY

The screen displays the real-time

discharging status. Press START/ENTER

key to alter discharge current. Press

START/ENTER key again to store the

parameter value you set. Press BATT

TYPE/STOP key to end the program.

Pb DISCHARGE
1.0A 12.0V(6P)

INC

DEC

- +

INC

DEC

- +

Batt type

Stop

Start

Enter ‘>3 seconds’

Pb-6 4.0A 12.59V
DCS 022:43 00682

Battery

type

Elapsed

time

Discharge

current

Battery

voltage

Discharged

capacity

Advertising