Chapter 10 vhdl monitor bfm, Inline monitor connection, Monitor bfm protocol support – Altera Mentor Verification IP Altera Edition AMBA AXI4-Stream User Manual
Page 157: Monitor timing and events, Figure 10-1. inline monitor connection diagram, Vhdl monitor bfm

Mentor Verification IP AE AMBA AXI4-Stream User Guide, V10.3
157
April 2014
Chapter 10
VHDL Monitor BFM
This section provides information about the VHDL monitor BFM. It has an API that contains
procedures to configure the BFM and to access the dynamic
during the life
of the transaction.
Inline Monitor Connection
The connection of a monitor BFM to a test environment differs from that of a master and slave
BFM. It is wrapped within an inline monitor interface and connected inline between a master
and slave, as shown in
. It has separate master and slave ports, and monitors protocol
traffic between a master and slave. The monitor has access to all the facilities provided by the
monitor BFM.
Figure 10-1. Inline Monitor Connection Diagram
Monitor BFM Protocol Support
The monitor BFM supports the full AMBA AXI4-Stream protocol.
Monitor Timing and Events
For detailed timing diagrams of the protocol bus activity, refer to the relevant AMBA
AXI4-Stream Protocol Specification chapter, which you can reference for details of the
following monitor BFM API timing and events.
The AMBA AXI4-Stream Protocol Specification does not define any timescale or clock period
with signal events sampled and driven at rising ACLK edges. Therefore, the monitor BFM does
Slave
Master
Inline monitor
Master port
Slave port
Monitor