Z8

®

CPU

User Manual

UM001604-0108

Instruction Description

199

Load External Data

Syntax

LDE dst, src

Instruction Format

Operation

dst

src

This instruction is used to load a byte from external data memory into a Working Register
or vice versa. The address of the external data memory location is specified by a Working
Register Pair. The contents of the source operand are not affected.

Example 1

If Working Register Pair R6 and R7 contain the value

40A2h

and external data memory

location

40A2h

contains the value

22h

, the statement:

LDE R2, @RR6

Op Code: 82 26

loads the value

22h

into Working Register R2. The value of external data memory loca-

tion

40A2h

is unchanged by the load.

Example 2

If Working Register Pair R6 and R7 contain the value

404Ah

and Working Register R2

contains the value

22h

, the statement:

LDE @RR6, R2

Op Code: 92 26

Cycles

OPC

(Hex)

Address Mode

dst

src

OPC

dst src

12

82

r

Irr

OPC

src dst

12

92

Irr

r

Flag

Description

C

Unaffected

Z

Unaffected

S

Unaffected

V

Unaffected

D

Unaffected

H

Unaffected

Advertising