17.10 Replacing a Single Acting Pilot Relay
Removal
1
Remove the Main Board. See procedure above.
2
Remove the two relay assembly screws.
3
Remove the single acting relay.
4
Remove the supply plug screw and O-ring.
5
Remove the Manifold gasket.
Installation
1
Place the Manifold gasket.
2
Place the supply plug O-ring and screw.
3
Place the single acting relay.
4
Place the two relay assembly screws.
5
Reassemble the main board and covers and calibrate.
Figure 51: Single Acting Relay Assembly
Base
Manifold
Gasket
Supply
Plug
Screw and
O-Ring
Single Acting
Relay
Relay Assembly
Screws (2)