E13: power-up/reset load source, E14: watchdog disable jumper, E15a, b, c: flash memory bank select – Delta Tau PMAC2A-PC/104 User Manual

Page 49: Adc inputs enable, E16: adc inputs enable

Advertising
background image

PMAC2A PC104 Hardware Reference Manual

Base Board E-Point Jumper Descriptions

43

E13: Power-Up/Reset Load Source

E Point and

Physical Layout

Location Description

Default

E13

E5

Jump pin 1 to 2 to reload firmware through
serial or bus port.

Remove jumper for normal operation.

No jumper

E14: Watchdog Disable Jumper

E Point and

Physical Layout

Location Description

Default

E14

B3

Jump pin 1 to 2 to disable Watchdog timer
(for test purposes only).

Remove jumper to enable Watchdog timer.

No jumper

E15A, B, C: Flash Memory Bank Select

E Point and

Physical Layout

Location Description

Default

E15A

E15C

E4

Remove all 3 jumpers to select flash memory
bank with factory-installed firmware.

Use other configuration to select one of the 7
other flash memory banks.

No jumpers installed

E16:

ADC Inputs Enable

E Point and

Physical Layout

Location Description

Default

E16

D1

Jump pin 1 to 2 to enable the Option-12
ADC inputs.

Remove jumper to disable the ADC inputs,
which might be necessary for reading
current feedback signals from digital
amplifiers.

No jumper