Oscillator Control Auto Cycle Storage Screens
There are a total of ten (10) Auto Cycle Storage Screens, and each screen is identified by the
“Auto Cycle Storage Number” (numbered 1 to 10) as shown in the following image. The units of
measure for the oscillation width (W) and the oscillation speed (S) are programmable (level 2 -
Advanced Programming Mode). If the units of measure change, all width and speed fields will
need to be manually converted. To make changes to these screens/fields use the “A”, “C” &
. rotary switches. All the Auto Cycle Storage Screens have the following features:
1
st
Field = The A Location Dwell Time. This sets the time duration that the oscillation stroke
will dwell (pause) each time the A location is reached. The choices available are
from 0.0 to 9.9 seconds in 0.1 second increments.
2
nd
Field = The C Location Dwell Time. This sets the time duration that the oscillation stroke
will dwell (pause) each time the C location is reached. The choices available are
from 0.0 to 9.9 seconds in 0.1 second increments.
3
rd
Field = the Oscillation Width. The value of this field sets the total width of the oscillation
stroke (A to C). The increments of adjustment and the minimum and maximum
allowable stroke widths are dependent on the preferred units of measurement (see
Oscillator Motor Setup Screen later in this manual for details). Note: - there is a
width range where the oscillation stroke is too small to permit A & C dwells to work.
4
th
Field = the Oscillation Speed. The value of this field sets the oscillation stroke speed.
The increments of adjustment and the minimum and maximum allowable stroke
speeds are dependent on the preferred units of measurement (see the Oscillator
Motor Setup Screen later in this manual for details).
1
st
Field
2
nd
Field
Units
3
rd
Field
Auto Cycle Storage Number
4
th
Field