IDK MSD-804FD User Manual
Page 37
MSD-804FD Users Guide (Command Guide)
37
@STP
Set test pattern
Command
format
@STP, ch_1, pattern_1, scroll_1 (, ch_2, pattern_2, scroll_2・・・)
Return value
format
@STP, ch_1, pattern_1, scroll_1 (, ch_2, pattern_2, scroll_2・・・)
Parameter
ch_1-4
: Output
0 = All outputs, 1 = OUT1 to 4 = OUT4
pattern_1-4
: Test pattern
0 = OFF [Default],
1 = VERTICAL COLOR BAR, 2 = HORIZONTAL COLOR BAR,
3 = VERTICAL GRAY SCALE, 4 = HORIZONTAL GRAY SCALE,
5 = VERTICAL LAMP, 6 = HORIZONTAL LAMP,
7 = 100% WHITE RASTER, 8 = 50% WHITE RASTER,
9 = 100% RED RASTER, 10 = 100% GREEN RASTER,
11 = 100% BLUE RASTER, 12 = CROSS HATCH,
13 = OUTPUT FRAME, 14 = VERTICAL STRIPE,
15 = HORIZONTAL STRIPE, 16 = VERTICAL ZEBRA,
17 = HORIZONTAL ZEBRA
scroll_1-4
: Scrolling
0 = OFF [Default], 1 = 3 pixel/frame to 10 = 30 pixel/frame
Scrolling the output test pattern takes [the set value × 3 = the number of pixels to
be scrolled per frame].
Example Send
Receive
@STP,1,1,0
@STP,1,1,0
Display “VERTICAL COLOR BAR“ to OUT1 without
scrolling.
Terminated normally.
Related info. 8.3.15 Test pattern