2 parameters for con units, 2 parameters, For con units – IHSE USA 481 Series Draco vario HDMI User Manual

Page 55: Configuration

Advertising
background image

Configuration

2013-08-13

55

Compression

Parameter

Function

MEDCPRATE Activate

medium compression rate

MINCPRATE

Activate low compression rate

MAXCPRATE

Activate high compression rate

Parallel Operation

Parameter

Function

KBDCON

Activate Keyboard Connect (only with redundant
CPU Units)

MOUCON

Activate Mouse Connect (only with redundant
CPU Units)

RELEASETIME=n

Release timer n = 0...9 seconds for Mouse and
Keyboard Connect, without parameter =
10 seconds

5.5.2 Parameters for CON Units

You can write the following parameters into the configuration file of a CON
Unit.

Output Settings

Parameter

Function

1080p50Hz

Always display 50 Hz when using 1920x1080

DISEXTOSD

Deactivate extender OSD

ENAFRAME

Show orange colored frame when losing
extender connection

ENAHOLDPIC

Show last transmitted picture highlighted by an
orange colored frame when losing connection

ENADDCTX

Activate DDC transmission by unplugging and
connecting the monitor back to the CON Unit