3. Manual Mode

The LP1600, in addition to being a powerful memory console, can also be used
as a simple two-scene preset board. This allows an untrained operator to
immediately start using the board, and learn it’s more advanced features as
time permits.

3.1. Startup

When the LP1600 is first turned on, the board will default into Run mode. The
Y/Presets switch will return to it’s previous state. Let’s assume this to be Y
mode, and further assume that all other effects (Chase and Stack) are turned
off.

The console will perform a brief test when power is applied. It will greet the
user with a message after the tests are performed:

LP-1600 v2.83L

Run Mode

In the case of a detected fault, an error message will display instead:

LP1600

Batt. LOW !

Error messages will be displayed for the following conditions:

Rom error
Ram error
Battery low
Buss Error (board non-functional)

Any error message indicates problems that must be repaired. For more
information regarding service, see the “Warranty and repair policy” heading of
this manual.

3.2. Channel Display

After the power on test is completed successfully, the sign on message is
replaced with a run-time message.