CV 118
Recovery Speed

Description

CV 118 adjusts the recovery speed for momentary interruptions in power

during operation.

RS0-RS7: Recovery Speed

0 = Disabled

1-127 = Absolute limiting: When set from 1 to 127, the

decoder will limit the recovery speed to the

corresponding speed step.

128 = Disabled

129-255 = Proportional limiting: When set from 129 to 255,

the decoder will limit its power after a power loss

to a specific percentage as calculated below:

Percentage = (CV 118 - 128) ÷ 127

Default Value: 204 (60%)