TRI TOOL INC.

92-1497 : Orig. 100728

Jam Nut

Paralle Offset

Jackscrews

Mandrel Shaft

Mounting and Adjusting the Miter Mandrel

Angular Offset

Adjustment Screws

MOUNTING THE DIAL INDICATOR KIT

Mount the Dial Indicator Kit onto the Mandrel and tighten the Thumb Screws

Adjust the dial indicator so the dial indicator adapter is grazing in contact with the
pipe.

If reference marks are to be used, the Dial indicator can be moved out of the way
and the pointer rod can be used alone to detect the reference marks.

Now your ready to fine adjust the Angular and Paralle Adjustments.