 For each signal the table check result will be displayed: “Table check predicted modes for signal

no. n: ….”.

 For each signal from the table check a code check will start: “Code check started, checking signal

no. n”

 Each code check will deliver a result when a mode is detected: “Mode detected for signal no. n” or

it will end with a timeout: “Code check finished”

 After the complete cycle the CCC will restart: “Restart…” and “Classifier start…”

Decoding

Process 4 and 5 complete the classification and code checking steps by automatically switching to decod-
ing of the detected mode.

In the case that a sampling spectrum contains multiple signals, and without any preference set in Code
Check Settings
, Signal #1 is automatically selected for decoding; otherwise the preference checked will
determine the selection for decoding.

Scan Delay in Automatic Modes

When W-SPECTRA is running in an automatic mode using a classifier code check and the classifier delivers
the first results, the automatic jump to the next frequency or to the next database entry will be defered
until the complete results by the code check are delivered.

Classifier Code Check Editor

The Classifier Code Check (CCC) option, which allows automatic classification and subsequent decoding
of monitored signals, is based on automatic parameter measurements. These code-base measurements
may however be replaced by, or be expanded with, table-based parameters. The table records are con-
tained in a XML database file which can be edited by the user using the CCC Editor.

Installation

The CCC Editor is a stand-alone application (CCC Editor.exe). It will be installed by the W-SPECTRA in-
stallation. After the installation the programm appears in C:\Program Files\WAVECOM\WSPECTRA.

At installation time the default data file is installed as CCC<DateCreated>DB.xml in
C:\Users\Public\PublicDocuments\WAVECOM\CCC Code Tables. The user may add any number of data-
base files using any file name – the extension must however always be .XML - as long as the files are cor-
rectly-formatted XML files consistent with the code table schema. Using this editor, correct formatting is
ensured.