14

Complete Automatic Monitoring System W-SPECTRAWAVECOM Monitoring System W-SPECTRA, W-

SPEED Manual V1.1.0

W-SPECTRA works properly.

 There are five major parts in the W-SPECTRA main GUI:

o

Direct receiver (SDR) control

o

Run a decoder or a classifier, database operations

o

Wideband (2 MHz) spectrum display and media player/recorder

o

Narrowband (96 kHz) spectrum display and media player/recorder

o

Decoder or classifier setting and display of results.

 The user can set the receiver frequency, demodulator and demodulator bandwidth using the W-

SPECTRA GUI or the native SDR GUI, e.g., WiNRADiO G39DDC GUI. Settings will be synchronised
in both GUIs.

 The user can view the spectrum up to 2 MHz in the wideband display.

 The signals in the middle 96 kHz wide stripe of the wideband display will be shown in the narrow-

band spectrum display. The user may move the middle cursor in the narrowband display to locate
the signal.

 The user may choose a classifier or decoder in the pull-down list “Mode” and the signal will be

classified or decoded. The result will be displayed in the lower part of the GUI.

 If no receiver (SDR) is running or the W-SPECTRA server stops, warning messages will be dis-

played in the W-SPECTRA GUI. The user may take actions according to the message guide.