Connecting the console cable, Setting terminal parameters – H3C Technologies H3C LSWM1WCM10 Access Controller Module User Manual

Page 17

Advertising
background image

10

Connecting the console cable

Step1

Connect the DB-9 female connector of the console cable to the serial port of the PC.

Step2

Connect the RJ-45 connector of the console cable to the console port of the access controller module or

the switch.

Setting terminal parameters

Step 1: Launch a terminal emulation program on a PC, for example, Terminal under Windows 3.1 and

HyperTerminal under Windows 95/98/NT/2000/XP.
Step 2: Set the parameters for the console terminal as follows:

Bits per second: 9600

Data bits: 8

Parity: none

Stop bits: 1

Flow control: none

Terminal emulation: VT100

Follow these steps to set the parameters:

1.

On the PC, select Start > All Programs > Accessories > Communications > HyperTerminal. The
Connection Description dialog box appears.

Figure 8 Set up a new connection

2.

Type a name, test in this example, for the new connection in the Name field and click OK. The
Connect To dialog box appears.

Advertising