Options 1–8

To set station 1 as a normally-closed master valve and assign it to any program, Program 1 (Option 1) through

Program 8 (Option 8).

Activate Option 1– to Activate Secondary Master Valve (Station 1)

Step 1 – Place the Function Dial to the Options position.

Step 2 – Use the

and

buttons to select the program to modify. Use the

and

buttons to set the Master

Valve to Master or Station 1.

Example: Set Program 2 to use Station 1 as a secondary master valve. Press the

or

button until

Option# 2 is displayed. Press the

or

button to toggle the Master Valve option to STN 1.

Step 3 – Repeat Step 2 to modify additional programs.
Step 4 – Return the Function dial to AUTO/RUN

position to exit Options.

Options 9 (Activate Exclusive Program with Start Sensor)

Option 9 is used in conjunction with the Start Sensor and Program 8. With Option 9 set to “PGM 8 Start=ON” and

the Start Sensor is activated, all automatic and manual watering will turn off and program 8 will immediately turn on.

Automatic programs will be suspended until the Start Sensor is deactivated. As long as the Start Sensor is activated,

Program 8 will continue to repeat its cycle.

Activate Option 

Step 1 – Place the Function Dial to the Options position. Press the

or

button until Option 9 is displayed.

Step 2 – Use the

or

button to activate or deactivate Option 9. When activated, program 8 will start when the

start sensor is triggered.

If program 8 has no value, the controller will function normally.

Step 3 – Return the Function dial to AUTO/RUN

position to exit Options.