Rear panel features and cabling, Caution – Extron Electronics MIX 301 User Manual
Page 11
MIX 301 • Installation and Operation
Rear Panel Features and Cabling
MIX 301
3 CHANNEL
MIXER
IN 2
MIX OUT
IN 1
IN 3
12V
0.5a MAX
2
1
4
6
5
3
Figure 3 — MIX 301 rear panel
1
Captive screw power input connector —
Connect the included
12 VDC external power supply into the 2-pole 3.5 mm captive
screw connector. Be careful to observe the correct polarity.
Captive Screw
Connector
Tie Wrap
Power Supply
Output Cord
Ridges
Smooth
A
A
SECTION A–A
5
3
CAUTION
When connecting the power supply, voltage
polarity is extremely important. Applying power
with incorrect voltage polarity could damage the
power supply and the MIX 301. Identify the power
cord negative (ground) lead by the ridges on the
side of the cord or a black heat shrink wrapping
around it.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
To verify the polarity before connection, check the no load
power supply output with a voltmeter.
Your MIX 301 may have shipped with a blue captive
screw connector. This blue connector can be plugged
into either a blue or an orange power receptacle.
The ideal length of exposed (stripped) copper wire
for the blue connector is 3/16" (5 mm).
7