G
ATEWAY INTERNAL PARAMETERS
These parameters are used in the ProfiDrive mode
Index Data type
R/W access
Description
802
Unsigned8 Read-write
Saving PZD setting to the gateway seeprom:
0 - nothing
1 - clear non-volatile PZD setting
2 - store the current PZD setting to non-volatile memory
3 - restore the PZD settings from non-volatile memory
These parameters are used to identificate the gateway application type and application version.
Index
Data type
R/W access
Description
800
Unsigned16 Read-write
Gateway application type
801
Unsigned16 Read only
Gateway application version
High byte - version
Low byte - subversion
P
ROFIDRIVE STANDARD PARAMETERS
These parameters are defined by profibus standard. They are used in ProfiDrive mode.
Index
Data type
Description
915 [8]
Unsigned16
(Array)
PZD configuring, setpoint telegram
Parameter is an array of 8 subindexes for defining output PZD slot
content (0=PZD0; 1=PZD1,... 10=PZD10).
916 [8]
Unsigned16
(Array)
PZD configuring, actual value telegram
Parameter is an array of 8 subindexes for defining input PZD slot
content (0=PZD0; 1=PZD1,... 10=PZD10).
918
Unsigned8
Gateway DP address
922
Unsigned16
Telegram selection
Value is 0 (telegram defined by 915,916 parameters)
964 [5]
Unsigned16
(Array)
Device identification
Array parameter with the following subindices meanings:
Manufacturer code, device type, version, year, day+month
965
Unsigned16
Profile version and subversion (first and second byte)
971
Unsigned16
Saving parameters to the flash
A change from 0 to 1 in this parameter value causes saving
application parameter to flash (so actually two writings to 971 are
needed for the request to save all parameters to flash).