PLANET WGSD-8020 User Manual
Page 154
User’s Manual of WGSD-8020
154
through 8.
•
Switch
Select the switch to which this ACE applies.
•
Any:
The ACE applies to any port.
•
Switch n:
The ACE applies to this switch number, where n is the number of
the switch.
•
Action
Specify the action to take with a frame that hits this ACE.
•
Permit:
The frame that hits this ACE is granted permission for the ACE
operation.
•
Deny:
The frame that hits this ACE is dropped.
•
Rate Limiter
Specify the rate limiter in number of base units. The allowed range is 1 to 15.
Disabled indicates that the rate limiter operation is disabled.
•
Logging
Specify the logging operation of the ACE. The allowed values are:
•
Enabled:
Frames matching the ACE are stored in the System Log.
•
Disabled:
Frames matching the ACE are not logged.
Please note that the System Log memory size and logging rate is limited.
• Shutdown
Specify the port shut down operation of the ACE. The allowed values are:
•
Enabled:
If a frame matches the ACE, the ingress port will be disabled.
•
Disabled:
Port shut down is disabled for the ACE.
The ACL configuration wizard is finished, and the new configuration is ready for use.
Figure 4-10-6