PLANET WGSD-8020 User Manual

Page 154

Advertising
background image

User’s Manual of WGSD-8020

154

through 8.

Switch

Select the switch to which this ACE applies.

Any:

The ACE applies to any port.

Switch n:

The ACE applies to this switch number, where n is the number of

the switch.

Action

Specify the action to take with a frame that hits this ACE.

Permit:

The frame that hits this ACE is granted permission for the ACE

operation.

Deny:

The frame that hits this ACE is dropped.

Rate Limiter

Specify the rate limiter in number of base units. The allowed range is 1 to 15.

Disabled indicates that the rate limiter operation is disabled.

Logging

Specify the logging operation of the ACE. The allowed values are:

Enabled:

Frames matching the ACE are stored in the System Log.

Disabled:

Frames matching the ACE are not logged.

Please note that the System Log memory size and logging rate is limited.

Shutdown

Specify the port shut down operation of the ACE. The allowed values are:

Enabled:

If a frame matches the ACE, the ingress port will be disabled.

Disabled:

Port shut down is disabled for the ACE.

The ACL configuration wizard is finished, and the new configuration is ready for use.