INSTALLATION REQUIREMENTS

Tools and Parts

Tools needed

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed

here.

Measuring tape

Pencil

Masking tape or

thumbtacks

Scissors

No. 3 Phillips screwdriver

for 1/4 - 20 x 3" (7.6 cm)

bolts

Drill

3/16"

(5 mm), 3/8" (1 cm),

5/8" (1.6 cm) drill bits

3/4" (1.9 cm) hole saw

Diagonal wire cutting

pliers

Stud finder

7/16" socket wrench

(or box wrench) for

1/4" x 2" lag screws

1½" (3.8 cm) diam. hole

drill bit for wood or metal

cabinet

Keyhole saw

Caulking gun and

weatherproof caulking

compound

Duct tape

Parts supplied

For information on reordering, see the “Replacement Parts”

section.

NOTE:

The hardware items listed here are for wood studs. For

other types of wall structures, be sure to use appropriate

fasteners.

NOTE:

Depending on model, grease filter and charcoal filter may

be combined.

Materials Needed

Standard fittings for wall or roof venting. See the “Venting Design

Specifications” section.

Location Requirements

IMPORTANT:

Check the opening where the microwave oven will

be installed. The location must provide:

Minimum installation dimensions. See the “Installation

Dimensions” illustration.

Minimum one 2" x 4" (5.1 x 10.2 cm) wood wall stud and

minimum 3/8" (1.0 cm) thickness drywall or plaster/lath

within cabinet opening.

Support for weight of 150 lbs (68 kg) which includes

microwave oven and items placed inside the microwave

oven and upper cabinet.

Grounded electrical outlet inside upper cabinet. See the

“Electrical Requirements” section.

NOTE:

Some cabinet and building materials are not designed

to withstand the heat produced by the microwave oven for

cooking. Check with your builder or cabinet supplier to make

sure that the materials used will not discolor, delaminate, or

sustain other damages.

Special Requirements

For Wall Venting Installation Only:

Cutout must be free of any obstructions so that the vent fits

properly and the damper blade opens freely and fully.

For Roof Venting Installation Only:

If you are using a rectangular-to-round transition piece, the

3" (7.6 cm) clearance needs to exist above the microwave

oven so that the damper blade can open freely and fully. See

“Rectangular to Round Transition” illustration in the “Venting

Design Specifications” section.

A. 3/16-24 x 3" (7.6 cm) round-head

bolts (2)

B. 1/4-20 x 3" (7.6 cm) flat-head

bolts (2)

C. Washers (2)
D. 3/16" (5 mm) toggle nuts (2)
E. 1/4" x 2" (0.6 cm x 5.1 cm) lag

screws (2)

F. Sheet metal screws 5/32" x 5/16"

(0.4 cm x 0.8 cm) (2)

G. Power supply cord bushing (1)
H. Damper assembly (for wall or roof

venting)

J. Exhaust vent cover (2)

A

B

C

D

E

F

G

H

J

Not Shown:

Mounting plate

(Located on the upper

polyfoam)

Grease filters

Charcoal filters

Advertising