Caution, Electrical information, Warning – Hearth and Home Technologies Dakota 42-CE User Manual

Page 10: A. ignition system wiring, B. remote control

Advertising
background image

10

Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 1/07

Battery polarity must be correct or module damage will
occur.

CAUTION

7

7

Electrical Information

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

CAUTION

Shock Risk
• Replace damaged wire with type 105° C rated wire.
• Wire must have high temperature insulation.

WARNING

BATTERY PORT

(4 AA BATTERIES)

VALVE

PILOT

IGNITION MODULE

6VDC

ON/OFF

SWITCH

THERMOCOUPLE

BLOCK

(CONNECTED TO
BACK OF VALVE)

PILOT GAS LINE

CONNECTED TO

BACK OF VALVE

IGNITION

MODULE

(6V)

ON/OFF

WALL SWITCH

VALVE

FLAME SPARKER/

SENSOR

ANT.

REMOTE

CONTROL

A. Ignition System Wiring

• This

fi replace is equipped with an electronic ignition

system which operates on a 6 volt system.

• The batteries are located within the ignition module which

is located within the external control box. A wiring diagram
is shown in Figure 7.1.

• The battery pack requires four AA batteries (not included).

See Section 11.B for battery replacement.

Figure 7.1 Electronic Ignition Wiring Diagram

B. Remote Control

• This fi replace is equipped with a remote control to

operate the ignition system.

• 9 volt battery required.
• Follow operating instructions included with remote

control.

Advertising