Table 3
Available Receptacles With Full Power Switch On
Switch Setting
Lower Voltage Receptacle
Higher Voltage Receptacle
120V
Rated Output is Available
Unavailable
120V/240V
Half of Rate Output is Available
Rated Output is Available
WARNING:
• TO TAKE OUT POWER FROM TWIST LOCK RECEPTACLE, INSERT THE PLUG INTO RECEP-
TACLE AND TURN CLOCKWISE TO LOCK IT.
• BE SURE TO GROUND THE GENERATOR IF THE CONNECTED ELECTRICAL EQUIPMENT IS
GROUNDED.
NOTE:
• When the circuit breaker turns off during operation, the generator is overloaded or the appliance is
defective.
• Stop the generator immediately, check the appliance and/or generator for overloading or defect and
repair as necessary.
I. STOPPING THE GENERATOR
(1) Set the power switch to OFF or unplug the cord from the receptacle.
(2) Move the throttle lever fully to the right.
(3) Turn the engine switch to the OFF position.
(4) Turn the fuel valve to the OFF position.
Figure 15: Fuel Valve
Operating Instructions
Page 20
Tsurumi’s Operation, Service, and Repair Manual