Refrigeration piping, Model oniz – Hill Phoenix ORIGIN2 ONIZ User Manual

Page 16

Advertising
background image

12

MODEL

ONIZ

REFRIGERATION PIPING

Refrigeration components and the

refrigeration outlet hole are located to provide
the best access for installation and mainte-
nance. As the diagram below indicates the coil
outlet hole is positioned forward on the right
hand side of the case, fully visible in front of the
fan plenum.

The expansion valve and other controls

are located on the left-hand side of the case
and are accessible without lifting the fan
plenum. The control cluster may be reached by
only lifting the left hand deck pan minimizing
the need to unload product.

Be sure to reseal the outlet hole after

installation, using a canned foam sealant and
white RTV

C

L

C

L

C

L

45 in

[114.2 cm]

22 1/2 in

[57.1 cm]

17 3/8 in

[44.1 cm]

9 11/16 in

[24.6 cm]

1 1/2 in [3.8 cm]

{FLAT END}

FRONT OF CASE

12 15/16 in

[32.9 cm]

**

22 1/2 in

[57.1 cm]

17 3/8 in

[44.1 cm]

9 11/16 in

[24.6 cm]

3 11/16 in [9.4 cm]

{WRAP END}

NOTES:

** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

z

SUCTION LINE - 7/8", LIQUID LINE - 1/2"

72 in [182.9 cm] {6' case}
96 in [243.8 cm] {8' case}

120 in [304.8 cm] {10' case}
144 in [365.8 cm] {12' case}

REFRIGERATION

6 1/2 in [16.5 cm]

9 5/8 in

[24.4 cm]

REMOVE SHIPPING BLOCKS

REMOVE THE SHIPPING BLOCKS
THAT PROTECT THE REFRIGERATION
LINES DURING SHIPMENT BEFORE
OPERATING THE CASE.