Hoshizaki KMS-1400MLH User Manual

Page 14

Advertising
background image

14

Components Energized when the Control Switch is in the SERVICE Position

When in the "SERVICE" position, the control switch supplies power

to the service switch and the machine is

in service mode.

The service switch has three positions: "DRAIN," "CIRC." and "W

ASH." See the information

below for details of each function.

DRAIN

Power is supplied to the pump and drain valve. This drains the wat

er tank.

CIRC.

Power is supplied to the pump only. This operation can be used to

circulate cleaner and

sanitizer for extended periods of time over the outside surface of

the evaporator.

WASH

Power is supplied to the pump and wash valve. This operation is

used to circulate cleaner

and sanitizer over both the inside and outside surfaces of the eva

porator.

4. Pump-Out Cycle

Legend:

Comp

- compressor

DWV -

drain water valve

FMR

- remote fan motor

FWV

- fill water valve

HGV

- hot gas valve

HWV

- harvest water valve

LF/S

- lower float switch contacts

LLV

- liquid line valve

PM

- pump motor

UF/S

- upper float switch contacts

KMS-1400MLH Sequence Flow Chart and Component Operation

1. One Minute

Fill Cycle

2. Harvest Cycle

3. Freeze Cycle

Pump motor stops

for



sec. and then

runs

for 10 sec.

Cycle Steps

FWV

energized

LF/S

open

LF/S

closed

Comp

energized

FMR

energized

HGV

energized

HWV

energized

FWV

de-energized

DWV

de-energized

Thermistor temp

reaches 48

°F (9°C)

(3.9 k

Ω

or less)

Harvest timer starts

LF/S

open

Comp

continues

FMR

continues

PM

continues

LLV

energizes

FWV

energized/

de-energized

for refill only

HGV

de-energized

LF/S

closed

Freeze cycle

operation turned

over to

LF/S

PM

de-energizes

 sec. ,

energizes for 10 sec.

Comp

continues

FMR

continues

DWV

energized

HGV

energized

LLV

de-energized

LF/S

check

LF/S

check

• Maximum harvest water valve time: 6 minutes

(HWV time is 6 minutes or the length of

harvest minus 50 sec., whichever is shorter.

PM energizes and runs for the last 50 sec. of

harvest.)

• Maximum harvest time:

0 minutes

Thermistor in

control

1 to 3 minute timer

in control

• Minimum freeze time: 5 minutes

• Maximum freeze time: freeze timer setting

• Lower float switch used to initiate water

tank refill (1 refill for KMS

-1400MLH)

• Upper float switch used to terminate

water tank refill (1 minute maximum fill

time)

5 minute timer

in control

Lower float

switch in

control

Initial startup always

begins here

"G" board will have

5

second delay

If

LF/S

is open, compressor stops and cycle returns to 1 minute fill

Factory set for every

10th cycle

50 sec.

PM

energized

HWV

de-energized

Advertising