B. diagnostic charts, No ice production – Hoshizaki KMS-1400MLH User Manual

Page 36

Advertising
background image

36

Problem

Possible Cause

Remedy

[1] The icemaker will not

start.

a) Power Supply

(Condensing Unit)

1. Off, blown fuse, or

tripped breaker.

1. Turn on, replace, or reset.

. Loose connections.

. Tighten.

3. Bad contacts.

3. Check for continuity and

replace.

4. Not within

specifications.

4. Refer to nameplate and

correct.

b) Water Supply

1. Water supply off or

pressure too low.

1. Check and get

recommended pressure.

c) High Pressure Control 1. Open contacts.

1. Check for continuity, let

reset or replace.

. Dirty condenser coil.

. Clean.

3. Refrigerant

overcharged.

3. Recharge.

4. Fan not operating.

4. See chart 1.[6]

5. Refrigerant line or

components plugged.

5. Clean and replace drier.

d) Thermostat

(Condensing Unit High
Temperature Safety)

1. Open contacts.

1. Let cool and reset. Check

for continuity and replace
if open.

e) Wire Harness Terminal

Block: Condensing Unit
and Icemaker

1. Loose connection.

1. Tighten.

f) Fuse (Icemaker fused

disconnect, if any)

1. Blown.

1. Check for short circuit and

correct. Reset or replace.

g) Fuse (10A fuse in

icemaker)

1. Blown.

1. Check for short circuit and

replace.

h) Control Switch

1. "OFF" position.

1. Move to "ICE" position.

. Bad contacts.

. Check for continuity and

replace.

3. Loose connection.

3. Tighten.

i) Transformer

1. Open windings.

1. Replace.

j) Bin Control

1. Tripped with bin filled

with ice.

1. Remove ice.

. Proximity switch stuck

open.

. Replace bin control.

k) Wiring to Control Board 1. Loose connections or

open.

1. Check for continuity and

replace.

B. Diagnostic Charts

1. No Ice Production

Advertising