HP COMPAQ DC5750 User Manual

Page 160

Advertising
background image

C–6

437963-001

Service Reference Guide, dc5750

POST Error Messages

1720-SMART Hard

Drive Detects Imminent

Failure

Hard drive is about to

fail. (Some hard drives

have a firmware patch

that will fix an erroneous

error message.)

1. Determine if hard drive is giving

correct error message. Enter

Computer Setup and run the Drive

Protection System test under

Storage > DPS Self-test.

2. Apply firmware patch if applicable

(available at www.hp.com/support).

3. Back up contents and replace hard

drive.

1796-SATA Cabling

Error

One or more SATA

devices are improperly

attached. For optimal

performance, the SATA 0

and SATA 1 connectors

must be used before

SATA 2 and SATA 3.

Ensure SATA connectors are used in

ascending order. For one device, use

SATA 0. For two devices, use SATA 0

and SATA 1. For three devices, use SATA

0, SATA1, and SATA 2.

1797-SATA Drivelock is

not supported in RAID

mode.

Drivelock is enabled on

one or more SATA hard

drives, and they cannot

be accessed while the

system is configured for

RAID mode.

Either remove the Drivelocked SATA

device or disable the Drivelock feature.

To disable the Drivelock feature, enter

Computer Setup, change Storage >

Storage Options > SATA

Emulation to IDE, and select File >

Save Changes and Exit. Reenter

Computer Setup and select Security >

Drivelock. For each listed

Drivelock-capable SATA device, ensure

Drivelock is Disabled. Lastly, change

Storage > Storage Options >

SATA Emulation back to RAID and

select File > Save Changes and

Exit.

1801-Microcode Patch

Error

Processor not supported

by ROM BIOS.

1. Upgrade BIOS to proper version.

2. Change the processor.

Invalid Electronic Serial

Number.

Electronic serial number

has become corrupted.

1. Run Computer Setup. If Setup

already has data in the field or will

not allow the serial number to be

entered, download from

http://www.hp.com and run

SP5572.EXE (SNZERO.EXE).

2. Run Computer Setup and try to enter

serial number under Security, System

ID, then save changes.

POST Error Messages (Continued)

Screen Message

Probable Cause

Recommended Action

Advertising