Freescale Semiconductor 802.15.4 User Manual

Page 50

Advertising
background image

7-2 Embedded Bootloader Reference Manual, Rev 0.0 Freescale Semiconductor

NOTE

All bits are enabled by default. Bits can only be disabled (erased in flash)
– never enabled. The bits are enabled again by the new firmware.

Input:

interface_state - The user selectable options. The below values should be
OR’ed together:

Embedded Bootloader control flags:

#define

NO_BIT_ENABLED

((uint8_t)0x00)

// Option: “Skip flash erase”

#define

ERASE_FLASH

((uint8_t)0x01)

// Option: “Do not reset after upload”

#define BOOT_AFTER_DOWNLOAD

((uint8_t)0x02)

// Option: “Erase production data”

#define

KEEP_NV_RAM

((uint8_t)0x04)

// Option: “Skip firmware checksum verification”

#define PERFORM_FLASH_VERIFICATION ((uint8_t)0x08)

NOTE

The Embedded Bootloader control flags correspond to the “optional
firmware upload settings” which can be disabled/enabled in the Zigbee
Flash Tool. See

Section 1.4.1, Embedded Bootloader Description

for

details.
The value is inverted. To enable the bit mask option, the setting must be
set to 0. To disable the bit mask option, the setting must be set to 1.

Use firmware_state – control if Embedded Bootloader or the application must be started.

To enable download, the setting must be = DO_UPDATE_FIRMWARE.

Embedded Bootloader boot flag:

#define EXECUTE_APPLICATION

((uint8_t)0x55)

#define DO_UPDATE_FIRMWARE

((uint8_t)0x00)

#define FLASH_EMPTY

((uint8_t)0xFF)

Output:

True - Ready for reset.

False - Something went wrong in changing the state.