Warning, Printer emulations – I-Data 812-1x MIO User Manual

Page 16

Advertising
background image

ida 812-1x MIO Operator’s Guide
Installation

-16-

WARNING!

The twinax cable must never be connected directly to
the twinax socket of the printer. It must always
be
connected to the T-cable.

3.4. Printer Emulations

On the ida 812-1x MIO it is possible to emulate the following IBM
printers once the interface card has been installed:

3812-1/5219

5224-2

5225-2

5256 -120

4234-2

Factory default is 3812-1/5219 emulation. You change this emulation
in the following way (provided that the printer has been configured
as described in Section 3.2, Printer Configuration Procedure)

1. Turn printer power OFF and disconnect the twinax cable.

2. Press and hold the [TEST] key on the interface and turn printer

power ON.

3. When the printer is ready the following will be printed:

"Current emulation is xxxx"

4. Turn the Device Address switch on the rear panel to the required

value according to the following table:

VALUE

EMULATION

0

3812-1/5219

1

5224-2

2

5225-2

3

5256-120

4

4234-2

5. Press the [TEST] key again and the selected emulation will be

printed.