39

The variable scan readout is connected with the ROI settings.
1. If ROI is set, these settings are applied to the partial scan settings.
2. If the multi ROI is used, the smallest number of the line and the largest number of the line

define the partial scan area.

3. In the case of sequence trigger, it is the same as for multi ROI. The smallest line and the

largest line define the partial scan.


In order to execute the partial scan, the fast dump should be ON.
















Fig.28 variable partial scan


How to calculate total line number and frame rate on variable partial scan mode

Variable partial scan The start line setting

1

st

line to 760

th

line

Readout height 8 lines to 768 lines

Total lines = ①OB period in the upper part of the frame (L) + ②Fast Dump period in the

upper part of the frame (L) + ③Readout lines(L) + ④Fast dump period in the
lower part of frame(L) +⑤Dummy transfer period

Where,

OB period in the upper part of the frame= 3L

Fast dump period for the upper part=

Round up

+ 1

Readout lines = Effective lines + 4L

Fast dump period for the lower part=

Round up

Dummy transfer period = 4L

Frame rate (fps) = Horizontal Frequency / Total lines

where, Horizontal Frequency 23.768KHz

Calculation example

Readout: 1/2 partial at the center (384L), Start line (193), End line (576)

Image Height

Image start line

Minimum: 8 lines

Maximum: 768 lines

Image starts at 1st line

1

760

8 lines

768 lines

 

When line number is set at 8 lines,

 

image starts at 760th line