Jameco Electronics Rabbit 3000 User Manual

Page 116

Advertising
background image

User’s Manual

107

Table 7-19. Input Capture Control/Status Register

Input Capture Control/Status Register

(ICCSR)

(Address = 0x56)

Bit(s)

Value

Description

7:2

(read)

These status bits (but not the interrupt enable bits) are cleared by the read of this
register, as is the Input Capture Interrupt.

7

0

The Input Capture 2 Start condition has not occurred.

(read)

1

The Input Capture 2 Start condition has occurred.

7

0

The corresponding Input Capture 2 Start interrupt is disabled.

(write)

1

The corresponding Input Capture 2 Start interrupt is enabled.

6

0

The Input Capture 2 Stop condition has not occurred.

(read)

1

The Input Capture 2 Stop condition has occurred.

6

0

The corresponding Input Capture 2 Stop interrupt is disabled.

(write)

1

The corresponding Input Capture 2 Stop interrupt is enabled.

5

0

The Input Capture 1 Start condition has not occurred.

(read)

1

The Input Capture 1 Start condition has occurred.

5

0

The corresponding Input Capture 1 Start interrupt is disabled.

(write)

1

The corresponding Input Capture 1 Start interrupt is enabled.

4

0

The Input Capture 1 Stop condition has not occurred.

(read)

1

The Input Capture 1 Stop condition has occurred.

4

0

The corresponding Input Capture 1 Stop interrupt is disabled.

(write)

1

The corresponding Input Capture 1 Stop interrupt is enabled.

3

0

The Input Capture 2 counter has not rolled over to all zeros.

(read)

1

The Input Capture 2 counter has rolled over to all zeros.

3

0

No effect on Input Capture 2 counter. This bit always reads as zero.

(write)

1

Reset Input Capture 2 counter to all zeros and clears the rollover latch.

2

0

The Input Capture 1 counter has not rolled over to all zeros.

(read)

1

The Input Capture 1 counter has rolled over to all zeros.

2

0

No effect on Input Capture 1 counter. This bit always reads as zero.

(write)

1

Reset Input Capture 1 counter to all zeros and clears the rollover latch.

1:0

0x

Normal Input Capture operation.

x0

Normal Input Capture operation.

11

Reserved for test. The Input Capture counter increments at both bit 0 and bit 8.
There is no carry from lower byte to higher byte.