Jameco Electronics Rabbit 3000 User Manual

Page 118

Advertising
background image

User’s Manual

109

Table 7-22. Input Capture Source x Register

Input Capture Source x Register

(ICS1R)

(Address = 0x59)

(ICS2R)

(Address = 0x5D)

Bit(s)

Value

Description

7:6

00

Parallel Port C used for Start condition input.

01

Parallel Port D used for Start condition input.

10

Parallel Port F used for Start condition input.

11

Parallel Port G used for Start condition input.

5:4

00

Use port bit 1 for Start condition input.

01

Use port bit 3 for Start condition input.

10

Use port bit 5 for Start condition input.

11

Use port bit 7 for Start condition input.

3:2

00

Parallel Port C used for Stop condition input.

01

Parallel Port D used for Stop condition input.

10

Parallel Port F used for Stop condition input.

11

Parallel Port G used for Stop condition input.

1:0

00

Use port bit 1 for Stop condition input.

01

Use port bit 3 for Stop condition input.

10

Use port bit 5 for Stop condition input.

11

Use port bit 7 for Stop condition input.

Table 7-23. Input Capture LSB x Register

Input Capture LSB x Register

(ICL1R)

(Address = 0x5A)

(ICL2R)

(Address = 0x5E)

Bit(s)

Value

Description

7:0

read

The least significant eight bits of the latched Input Capture count are returned.
Reading the lsb of the count latches the msb of the count to avoid reading stale
data. Reading the msb of the count opens the latches.

Table 7-24. Input Capture MSB x Register

Input Capture MSB x Register

(ICM1R)

(Address = 0x5B)

(ICM2R)

(Address = 0x5F)

Bit(s)

Value

Description

7:0

read

The most significant eight bits of the latched Input capture count are returned.

Advertising
This manual is related to the following products: