Installation (for qualified installers only), Vent location, Vent configurations – Lopi DVL Insert EF II User Manual

Page 15: Inlet & exhaust re-line exhaust only re-line

Advertising
background image

Installation (for qualified installers only)

15

© Travis Industries

4060111

100-01174

Vent Location

A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures
proper combustion for all vent configurations. Depending upon the vent configuration, you
may be required to adjust the restrictor position. The charts for acceptable vent configurations
detail the correct vent restrictor position.

2”

Center Line

Inlet (3” Dia.)

Exhaust (4” Dia.)

Fireplace

Opening

1-1/2”

4-1/2”

14-3/4”

5-1/8”

NOTE: Vent location changes based

upon restrictor position. Position # 1 is

shown to the right. Each restrictor

position moves the vent location forward

(toward the fireplace opening)

approximately 1/4”.

Vent Configurations

Z.C. (Metal) Wood-Burning Fireplace

Inlet & Exhaust Re-Line

Exhaust Only Re-Line

Direct Vent Cap

(part # 991)

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

6-5/8" to 3" & 4" Colinear

Adapter & Flashing

(Travis Part # 98900124)

A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Masonry Fireplace

Any cracks or
damage inside the
chimney must be
repaired.

Exhaust

4" dia.

Gas Liner

Inlet

3" dia. Gas Liner

Exhaust

4" dia. Gas Liner