Installation (for qualified installers only)

© Travis Industries

4060111

100-01174

Installation Without Surround Panels

The insert may be installed without surround panels. Mount the on/off switch and rheostat to the
control panel under the burner pan (see “Installation of the On/Off Switch and Rheostat” on page 19).

Surround Panel Installation

PANEL SIZE

WIDTH

HEIGHT

PART #

8" x 10" Rectangular

44-3/16"

33-3/8"

98500606

Arched (8” x 10”)

44-3/16"

33-3/8"

98500608

10” x 13” Rectangular

48-3/16"

36-3/8"

98500607

1

Follow the directions below to install the side panels.

Line up each side surround

panel and insert two screws from

the inside to secure in place.

5/16" Nutdriver

Pre-thread the holes on the surround

panels with the screws included in the

surround panel kit.

b

a

Run the rheostat wires,

on/off switch wires, and

power cord through the

access hole on the

insert

2

Follow the directions below to install the top panel.

Install the top panel so the

two tabs insert into the slots

on the side panels.

Top
Panel

Top Trim

"L" Bracket

Right Side Trim

Slot for on/off
switch and hole
for rheostat

NOTE:

These 3/8"

stand-offs are

not required

and may be

flattened.

The insulation included with the

panels may be discarded.

a

Construct the panel trim. Insert one leg of each "L"

bracket into the top and side trim piece. Align the

trim to form a precise corner, then tighten the two set

screws with a small standard screwdriver. Slide the

trim over the panels.

Tighten the set

screws from the back

side with a small

standard screwdriver

"L" Bracket

Right Side
Trim

Top Trim

b