Installation

Issue 1 June 1998

3-5

Following installation, administer the line and station ports that use
the Switch Module according to the instructions in DEFINITY®
Communications System Generic 3 Implementation Guide, Issue
1,
document #555-230-655.

Follow these steps to install the Switch Module:

1. Ensure that the module has the proper DIP switch configuration

(see Table 3-1).

Table 3-1. DIP Switch Configuration

Switch #

OFF

ON

1

µ

-Law companding

A-Law companding

2

Normal operation

Reserved

3

Normal operation

Reserved

4

Normal operation

Test mode

NOTE:
You should not change the factory-set DP switches; all DIP
switches be set at OFF. Check with your system administrator
before making changes.

!

CAUTION

:

Do not plug the A/C adapters into the electrical outlets until
instructed to do so in the following procedure.