Message Description

Action

No Net Found

xxxxxxxxxxxx yy

x…x = AP MAC address

yy = AP signal strength

Handset cannot find a suitable AP; displays

MAC and signal strength of “best” non-

suitable AP found.

Check AP and handset network settings

such as ESSID, Security, Reg domain and

Tx power.

Ensure APs are configured per

Configuration Guide

.

Try Site Survey mode to determine more

specific cause.

No Reg Domain

Regulatory Domain not set

Configure the Regulatory Domain of the

handset

No SW Found

A required software component has not been

properly identified.

Check that the handset license type has a

corresponding entry in the slnk_cfg.cfg

file.

Check that the pd11skd.bin and

pi110001.bin entries exist under this

license type in the slnk.cfg.cfg file.

Not Installed!

A required software component is missing

Check that all required software files are

on the TFTP server, if over-the-air

downloading is being used. If the error

repeats, contact SpectraLink Technical

Support.

Press End Call

Your call has ended

Press the

End Call

key to return to

standby mode.

Restarting

The handset is in the process of rebooting.

There will be a 20 second delay in an attempt

to let potential network/system errors clear.

None

Select License

The correct protocol has not been selected

from the license set.

Using the administrative menus, select one

license from the set to allow the handset to

download the appropriate software.

Server Busy

Handset is attempting to download from a

TFTP server that is busy downloading other

devices and refusing additional downloads.

None, the handset will automatically retry

the download every few seconds.

SKT Open Failed

Socket open fail. Occurs when the handset

tries to connect to the PBX but there is no

response. If resiliency is active, the handset

will keep trying.

If the PBX is inoperative and resiliency is

not active or the handset cannot locate a

backup PBX, turn off the handset and

repair the primary PBX. Note that it may be

advisable to reconfigure the backup PBX to

be the primary PBX if the repair is more

time-consuming than the reconfiguration.

Storing Config

Handset is storing changes to handset

configuration.

None. Informational only. The handset may

display this briefly following a

configuration change or software

download.

SVP Service Rej.

The NetLink SVP Server has rejected a

request from the handset

The handset will restart and attempt to re-

register with the SVP Server, which should

fix the problem. Report to your

administrator if it keeps happening.

System Busy

yyy.yyy.yyy.yyy

y…y = SVP Server IP Address

SVP Server has reached call capacity.

All call paths are in use, try the call again

in a few minutes.