13 In the Fast Configuration Wizard - SIP dialog box, enter the following

information:

14 Click the Next button.
15 Enter the required Security information in the dialog box.

Field

Description

SIP Server

Select:

Specify – to manually configure SIP servers.

Off – if SIP servers are not present in the network.

SIP Server IP
Address

Enter either the IP address of the preferred SIP server
or its host name (if a DNS server is used).

Transport Type

Select the protocol that is used for signaling between
the MCU and the SIP Server or the endpoints
according to the protocol supported by the SIP Server:
UDP – Select this option to use UDP for signaling.
TCP – Select this option to use TCP for signaling.
TLS – The Signaling Host listens on secured port
5061 only and all outgoing connections are
established on secured connections. Calls from SIP
clients or servers to non secured ports are rejected.
The supported security protocols are: TLS 1.0, SSL
2.0 and SSL 3.0.

Field

Description

Authentication
User Name

Enter the conference, Entry Queue or Meeting Room
name as registered with the proxy.
This field can contain up to 20 ASCII characters.

Authentication
Password

Enter the conference, Entry Queue or Meeting Room
password as defined in the proxy.
This field can contain up to 20 ASCII characters.