Configuring rs-232 equipment, Configuring for use with a touch panel control, Configuring rs-232 equipment -29 – Polycom VSX Series User Manual

Page 119: Configuring for use with a touch panel control -29

Advertising
background image

Customizing the VSX System

4 - 29

Configuring RS-232 Equipment

The VSX 5000, VSX 6000, VSX 6000A, VSX 7000, and VSX 7000s systems

provide one RS-232 port; the VSX 7000e and VSX 8000 systems provide two.

1.

Go to System > Admin Settings > General Settings > Serial Port.

2.

Configure these settings:

Configuring for Use with a Touch Panel Control

VSX systems that have a serial port can be configured for use with a touch

panel control.

To configure the serial port for a touch panel:

1.

Go to System > Admin Settings > General Settings > Serial Port.

2.

Configure these settings:

Setting

Description

Baud Rate

Set the baud rate to the same value that it is set on the
serial device.

RS-232 Mode

Specifies the mode used for the serial port. Available
settings depend on the VSX system model.

Control—Receives control signals from a touch-panel
control.

Sony PTZ—Provides control signals to a PTZ camera.
(VSX 7000, VSX 7000s, VSX 7000e, VSX 8000)

Closed Caption—Receives closed captions from a
captioning service using a modem, or directly from a
captioner’s computer via Telnet.

Vortex Mixer—Provides control signals to a Polycom
Vortex mixer.

Pass Thru—Passes data to an RS-232 device
connected to the serial port of the far-site system.

Polycom Annotation—Provides control signals to the
Polycom Instructor RP™.

Debug—Provides a Telnet trace for debugging. You
can only set one RS-232 port at a time to Debug mode.

Setting

Description

Baud Rate

Set the baud rate to the same value that it is set on the
touch panel control.

RS-232 Mode

Select Control. This allows any device connected to the
RS-232 port to control the system using API commands.

Advertising