P. 38), Interlock output control setting, Interlock output terminal setting – TOA Electronics M-9000 User Manual

Page 38: Channel number selection

Advertising
background image

38

Volume increasing level setting

C - I N 0 1 – V O L U P

0 5

.

Volume decreasing level setting

C - I N 0 1 – V O L D W N

0 5

.

Set the volume level (dB) to increase or decrease.

Interlock output control setting

C - I N 0 1 – S Y N C

O F F

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.

Interlock output terminal setting

C - I N 0 1 –

C O U T 0 1

This screen is displayed only when the interlock output control setting is set to ON.
Set the control output terminals 1 – 4 (1 – 12 when the C-001T is used) which are closed in synchronization
with the control input of the set number. Avoid using the control output terminals designated as interlock
output terminals in the Event setting.

(When the control input function is set to MUTE:)

C - I N

0 1

M U T E

Assign the function that mutes the input or output channel to the control input.
Closing the control input terminal mutes the set channel.

Channel number selection (MUTE)

C - I N 0 1 – M U T E

I N 1

Using the Input channel or Output channel selection key, select the channel number to be muted.

(When the control input function is set to POWER:)

C - I N

0 1

P O W E R

Assign the power ON/OFF function to the control input. Power turns on when the control input terminal is
closed, and turns off when the control input terminal is opened.

(When the control input function is set to EMG-MUTE:)

C - I N

0 1

E M G - M U T E

Assign the function that simultaneously mutes all output channels to the control input. Closing the control input
terminal mutes all output channels. This function is used to cut off the output provided from the unit during
emergency broadcast operation.

Advertising